About this product
Smart Home Device ConnectivityHomeplug
Warranty Duration1 Month
Warranty TypeManufacturer Warrenty
Product description
Temperature range: -50°C~110°C
Temperature control range: -50°C~110°C
Temperature measurement accuracy: ± 0.2 °C
AC 110-220V split type transformer, temperature control range: -50℃~+100℃, direct output.
Temperature control accuracy: ± 0.1 °C
Input power: DC12V/DC24V/AC220V
Output power: 120W/240W/1500W
Output type: direct output
Mounting hole distance: 73mm (aperture 4mm)
Appearance size: 60 × 45 × 31mm
Introduction to Code and Features:
P0 sets the initial temperature:
Press the SET button to enter the internal menu. The default display is P0. Press the SET button again to set the desired initial temperature with the up and down buttons.
P1 set the stop temperature:
Press the SET button to enter the internal menu, the P0 screen. Press the up and down buttons to change to P1. Press the SET button again to set the desired stop temperature.
P2 set temperature correction:
In the same way, enter the internal menu, change it to P2By pressing the up and down button, press the setting button again and set the desired calibration temperature by the up and down button. (Detection temperature + correction temperature = actual temperature)
P3 Set the default delay:
In the same way, enter the internal menu, change it to P3By pressing the up and down buttons, press the setting button again, and set the desired delay time by the up and down buttons, the unit is minutes. (Note: Delay start is generally used for compressor refrigeration. If English refrigerator freezer, this value must be set. According to the compressor back pressure, it is generally set for 3-6 minutes. If it is not used to control the refrigeration of the compressor, it is not necessary to expand. direct skip time function)
Cooling mode: start temperature > stop temperature (the program automatically
determines the cooling mode)