•1.Temperature measuring range: -50 C ~ 99 C
•2.Resolution: 0.1 C;
•3.Accuracy:+- 1 C (-50 C ~ 70 C);
•4.Sensor error delay: 1 minute
•5.Power supply:AC 110-220V 50/60Hz
•6.Power consumption: <3W;
•7.Sensor: NTC sensor (1PC);
•8.Relay contact capacity:Two Relay Cool 10A/220VAC; Heat 10A/220VAC;
•9.Ambient temperature: 0 C ~ 60 C;
•10.Storage temperature: -30 C ~ 75 C;
•11.Relative humidity: 20% ~ 85%(No condensate)
•12.Sensor length: 1.0m
•13. Front Panel Size: 75x34.5mm ; Product Size: 75x34.5x85 mm ; Mounting Size: 71x29mm
Please set it to C when the high temperature starts in cooling mode
Low temperature startup is heating mode, please set it to H
In heating mode (H): measured value ≤ set value - when the hysteresis starts, the output heats up to the set value and stops
In cooling mode (C): When the measured value ≥ set value + hysteresis, start output cooling until the set value stops
P2 maximum setting range: the maximum value does not exceed this value when setting the temperature
P3 minimum setting range: the minimum value is not lower than this value when setting the temperature
P4 temperature correction
When there is a deviation between the measured temperature and the standard temperature, this function can be used to correct, the corrected temperature = the temperature before correction + the corrected value
P5 delay start time unit: minute
When controlling the refrigeration of the compressor equipment, the delay time can be set according to the needs. When the controller outputs, the equipment will not start immediately, and it needs to run after the set delay time.
P6 high temperature alarm
When the measured value is greater than this value, the screen will display --- and beep alarm, and at the same time, the output will be forcibly disconnected
Turn on the data lock to keep the current setting unchanged. At this time, the set temperature and function are invalid. If you need to modify it, you need to turn off the data lock function
Long press SET to switch to P8, press SET once to set to on, press Rst to restore factory settings
You can also press and hold the +- key for power-on self-test and restore factory settings
Please connect the power supply according to the parameters and circuit diagram, and connect the cooling or heating equipment to the output terminal
Enter the internal setting to select heating (enter P0 to select H) or cooling (enter P0 to select C) mode as needed
Set the temperature method: press Set once and the screen flashes, press up and down to set the desired temperature, press Rst to confirm and return
OUT indicator light on the panel: flickering means cooling or heating start delay, constant light means output
Nixie tube: display LLL means the sensor is open; display HHH means the temperature controller will forcibly cut off the power if it exceeds the measurement range; display --- means high temperature alarm